A genuine classic emulsion black-and-white film, and one of the very few still in production. Adox introduced CHS 100 II in 2014 to fill the gap left when Fotokemika in Croatia shut down and took the old Efke emulsions with it — the same emulsions Adox had sold for years as CHS Art. Rather than reviving that exact recipe, Adox developed a new single-layer, silver-rich cubic-grain emulsion coated in Germany, keeping the character of the originals while improving consistency and handling.The single-layer construction is the film's point. Modern emulsions stack several layers of differing sensitivity to build contrast and tame highlights; CHS 100 II doesn't, which gives it a long, unhurried tonal scale, high acutance, and a rendering that reads as mid-century rather than contemporary. Panchromatic with sensitivity extending unusually far into the red. Available in 35mm, 120, and sheet formats, including large and ultra-large sizes.
仕様
表 1- 公称 ISO
- 100
- 処理方式
- 白黒
- ステータス
- 現行品
- 初発売
- 2013
- 販売フォーマット
- 記載なし
- ベースフィルムベース 乳剤を支える、透明で柔軟な支持体。 用語集で詳しく読む ›
- PET
- 乳剤乳剤 フィルムの感光層。ゼラチンに保持された微細なハロゲン化銀の結晶。 用語集で詳しく読む ›
- ハイブリッド
- 分光感度分光感度 フィルムがどの色の光にどの程度反応するか。 用語集で詳しく読む ›
-
オルソクロマチック — これは何を意味するか
青と緑に感光し、赤にはほとんど感光しません。赤は非常に暗く、青は明るく写るため、肌のしみが目立ち、空が白っぽくなります。その代わり、濃い赤の安全光の下で扱えるため、現像の様子を見ながら作業できます。
- 粒状性(RMS)粒状性 写真に見える砂のような質感で、像を形成する銀や色素の塊に由来するもの。 用語集で詳しく読む ›
- 記載なし
- 解像力, 本/mm
- 記載なし
- 最大濃度濃度 ネガ、透過原稿、プリントが光をどれだけ遮るか。 用語集で詳しく読む ›
- 記載なし
- ラチチュード(オーバー側)露出ラチチュード 露出オーバーやアンダーになっても、使える結果が得られる許容範囲。 用語集で詳しく読む ›
- 記載なし
- ラチチュード(アンダー側)
- 記載なし
ダッシュは、データシートから読み取れていない数値です。ここに推定値は一切ありません。
現像時間
計算機で開く ›設定感度 — 公称感度に印
公表された時間 42 件中 40 件を表示
| 現像液 | 希釈 | EI | 温度 | 時間 | 撹拌 | 出典 |
|---|---|---|---|---|---|---|
| Fomadon Excel W27 | 原液 20.0 °C | 100 | 9:00 | — | ||
| Fomadon LQN | 1+10 20.0 °C | 100 | 9:00 | — | ||
| Fomadon P | 原液 20.0 °C | 100 | 7:00 | — | ||
| Fomadon R09 | 1+50 20.0 °C | 100 | 9:30 | — | ||
| Rodinal | 1+25 20.0 °C | 100 | 5:30 | — | ||
| Rodinal | 1+50 20.0 °C | 100 | 12:30 | — | ||
| D-76 | 1+1 20.0 °C | 100 | 9:00 | — | ||
| D-76 | 原液 20.0 °C | 100 | 6:30 | — | ||
| ID-11 | 1+1 20.0 °C | 100 | 7:30 | — | ||
| Rodinal | 1+100 20.0 °C | 100 | 30:00 | — | ||
| FX-39 Type II | 1+9 20.0 °C | 100 | 7:30 | — | ||
| Rodinal | 1+25 20.0 °C | 100 | 5:30 | — | ||
| Rodinal | 1+50 20.0 °C | 100 | 12:30 | — | ||
| Atomal 49 | 原液 20.0 °C | 100 | 6:30 | — | ||
| Atomal 49 | 1+1 20.0 °C | 100 | 10:00 | — | ||
| FX-39 Type II | 1+19 20.0 °C | 100 | 13:00 | — | ||
| Silvermax Developer | 1+19 20.0 °C | 100 | 8:30 | — | ||
| Ilfotec DD-X | 1+4 20.0 °C | 100 | 7:00 | — | ||
| ID-11 | 1+1 20.0 °C | 100 | 7:30 | — | ||
| D-76 | 原液 20.0 °C | 100 | 6:30 | — | ||
| D-76 | 1+1 20.0 °C | 100 | 9:00 | — | ||
| HC-110 | Dilution B (1+31) 20.0 °C | 100 | 5:30 | Kodak — 最初30秒、その後30秒ごとに5秒 | ||
| HC-110 | Dilution D (1+39) 20.0 °C | 100 | 7:00 | Kodak — 最初30秒、その後30秒ごとに5秒 | ||
| HC-110 | Dilution E (1+47) 20.0 °C | 100 | 9:00 | Kodak — 最初30秒、その後30秒ごとに5秒 | ||
| XTOL | 1+1 20.0 °C | 100 | 8:00 | — | ||
| Rodinal | 1+25 20.0 °C | 100 | 5:30 | — | ||
| Rodinal | 1+50 20.0 °C | 100 | 12:30 | — | ||
| Atomal 49 | 原液 20.0 °C | 100 | 6:30 | — | ||
| Atomal 49 | 1+1 20.0 °C | 100 | 10:00 | — | ||
| FX-39 Type II | 1+19 20.0 °C | 100 | 13:00 | — | ||
| Silvermax Developer | 1+19 20.0 °C | 100 | 8:30 | — | ||
| Ilfotec DD-X | 1+4 20.0 °C | 100 | 7:00 | — | ||
| ID-11 | 1+1 20.0 °C | 100 | 7:30 | — | ||
| D-76 | 原液 20.0 °C | 100 | 6:30 | — | ||
| D-76 | 1+1 20.0 °C | 100 | 9:00 | — | ||
| HC-110 | Dilution B (1+31) 20.0 °C | 100 | 5:30 | Kodak — 最初30秒、その後30秒ごとに5秒 | ||
| HC-110 | Dilution D (1+39) 20.0 °C | 100 | 7:00 | Kodak — 最初30秒、その後30秒ごとに5秒 | ||
| HC-110 | Dilution E (1+47) 20.0 °C | 100 | 9:00 | Kodak — 最初30秒、その後30秒ごとに5秒 | ||
| XTOL | 1+1 20.0 °C | 100 | 8:00 | — | ||
| HRX | 1+17 20.0 °C | 100 | 11:00 | — |
現像液別の現像時間
現像液 14 種- Atomal 49 — Atomal 49 での CHS 100 II 4
- D-76 — D-76 での CHS 100 II 6
- FX-39 Type II — FX-39 Type II での CHS 100 II 3
- Fomadon Excel W27 — Fomadon Excel W27 での CHS 100 II 1
- Fomadon LQN — Fomadon LQN での CHS 100 II 1
- Fomadon P — Fomadon P での CHS 100 II 1
- Fomadon R09 — Fomadon R09 での CHS 100 II 1
- HC-110 — HC-110 での CHS 100 II 6
- HRX — HRX での CHS 100 II 1
- ID-11 — ID-11 での CHS 100 II 3
- Ilfotec DD-X — Ilfotec DD-X での CHS 100 II 2
- Rodinal — Rodinal での CHS 100 II 7
- Silvermax Developer — Silvermax Developer での CHS 100 II 4
- XTOL — XTOL での CHS 100 II 2
特徴
Tonality: long, gently rising curve with generous shoulder. Highlights hold on much longer than a modern 100-speed film before blocking up; midtones are where it separates best.
Grain: cubic, clearly visible, sharp-edged rather than mushy. Not fine by modern standards — closer to the look of a 1960s emulsion than to Delta or T-Max.
Sharpness: excellent. The thin single-layer coating gives strong edge definition, which is a large part of why the grain reads as crisp rather than soft.Red sensitivity: extended, so reds and warm skin render lighter than expected and skies go paler without a filter. A yellow or orange filter has a stronger effect here than on most panchromatic films.
Glow: highlights bloom slightly around hard light sources — a characteristic of thin classic emulsions and a large part of why people choose it.
Latitude: wide on the overexposure side, less forgiving under. Many shooters rate it at EI 50–80 to open the shadows.
Developers: Rodinal/Adonal 1+50 is the traditional pairing and emphasises the sharpness and grain. Atomal 49 or D-76/ID-11 tames the grain and gives a softer, more compact scale. XT-3 sits between.
Handling: the emulsion is softer than modern films. Wash and squeegee carefully; avoid hardening-free workflows getting warm, and expect 120 to curl.
Best suited to: landscape, architecture, still life, portraiture in soft light — subjects with long tonal ranges and time to expose carefully. Less suited to fast handheld work or scenes needing clean shadow detail at box speed.
In one line: the closest thing currently in production to what black and white film looked like before multi-layer coating.
このページへのリンク
レビュー 0 件
写真家が自身のプロフィールで書いたレビューです。何を撮っている人の意見なのかを見たうえで判断できます。
時間の提案、または誤りの報告
CHS 100 II の時間で、ここにないものや誤っているものをご存じですか? 出典とともにお知らせください。キュレーターが確認します。
- 出典のみ. 時間は、一次資料(メーカーのデータシートまたはチャート)から読み取れた場合にのみ掲載します。そのリンクがあれば、お寄せいただいた情報を確認できます。
- 自動では掲載されません. ページの内容が変わる前に、すべての報告を人間が読みます。
- アカウント不要. お名前とメールアドレスは任意で、返信のためだけに使用します。
コメント 0 件
実際の使用感についてのメモ。現場での挙動は、データシートの記載と同じくらい価値があります。
まだコメントはありません。実際の使用感を最初に教えてください。