Skip to content

Ortho Plus

ISO 80 B&W negative B&W In production
Ilford Ortho Plus

Specification

Table 1
Nominal ISO
80
Process
B&W
Status
In production
First released
not given
Available formats
not given
BaseFilm base The clear, flexible support that carries the emulsion. Read more in the glossary ›
not given
EmulsionEmulsion The light-sensitive layer of a film: tiny crystals of silver halide held in gelatin. Read more in the glossary ›
not given
Spectral sensitivitySpectral sensitivity Which colours of light a film responds to, and how strongly. Read more in the glossary ›
Orthochromatic — what this means

Sensitive to blue and green but effectively blind to red. Reds go very dark and blues go light, which is why skin blemishes stand out and skies wash out. The compensation is that it can be handled under a deep red safelight, so you can watch it develop.

Grain (RMS)Grain The visible, sand-like texture in a photograph that comes from the clumps of silver or dye that form the image. Read more in the glossary ›
not given
Resolving power, line pairs / mm
not given
Maximum densityDensity How much light a negative, transparency or print blocks. Read more in the glossary ›
not given
Latitude overExposure latitude How far a film can be over- or underexposed and still give a usable result. Read more in the glossary ›
not given
Latitude under
not given

A dash means the figure has not been read off a datasheet. Nothing here is estimated.

Development times

Open in the calculator ›
Clear

Showing 15 of 15 published times.

Developer Dilution EI Time Source
ID-11 1+1 20.0 °C 80 10:30
Verified Datasheet Report
ID-11 1+3 20.0 °C 80 16:00
Verified Datasheet Report
ID-11 stock 20.0 °C 80 8:00
Verified Datasheet Report
Ilfosol 3 1+14 20.0 °C 80 7:00
Verified Datasheet Report
Ilfosol 3 1+9 20.0 °C 80 5:00
Verified Datasheet Report
Ilfotec DD-X 1+4 20.0 °C 80 10:30
Verified Datasheet Report
Ilfotec HC 1+15 20.0 °C 80 4:00
Verified Datasheet Report
Ilfotec HC 1+31 20.0 °C 80 6:00
Verified Datasheet Report
Microphen 1+1 20.0 °C 80 11:30
Verified Datasheet Report
Microphen 1+3 20.0 °C 80 13:30
Verified Datasheet Report
Microphen stock 20.0 °C 80 9:00
Verified Datasheet Report
Perceptol stock 20.0 °C 80 13:00
Verified Datasheet Report
Ilfotec DD 1+4 24.0 °C 80 5:30
Verified Datasheet Report
Ilfotec RT Rapid 1+1+2 26.0 °C 80 1:05
Verified Datasheet Report
Ilfotec RT Rapid 1+1+5 26.0 °C 80 1:18
Verified Datasheet Report

Link to this page

0 reviews

Written by photographers, under their own profile — so you can see what they shoot before you weigh what they say.

Help keep it right Form R-1

Suggest a time or report a mistake

Know a time for Ortho Plus that is missing here, or spotted one that is wrong? Tell us, with the source, and a curator will check it.

  • Sources only. We publish a time only when it has been read off a primary source: the maker’s datasheet or chart. A link to it is what lets us check yours.
  • Nothing goes up by itself. Every report is read by a person before anything on the page changes.
  • No account needed. Your name and email are optional, and only to reply to you.
What would you like to send?

A datasheet, the maker’s chart or technical publication. Forums and blogs can’t be checked the same way.

0 comments

Notes on how this behaves in practice — what it does in the field is worth as much as what the datasheet says.

Comments from visitors without an account are read by a moderator before they appear.

JPEG, PNG or WebP, up to 25 MB each. A frame is worth more than a paragraph.

Plain text. Up to 4,000 characters.

No comments yet. Be the first to say how it actually behaves.