Skip to content

Reciprocity

Kentmere Pan 100 long exposures

What a metered time becomes on Pan 100, and the stops it adds — worked out from Kentmere’s own data, never past it.

Form T-2

Your metered time

Tc = Tm^P for metered times over 1 s; 1 s or less needs no correction (P = 1.26)

The maker’s reciprocity data ↗

Table 1

At a glance

Metered Expose for Added
1 s 1 s —
2 s 2.4 s +0.3 stops
4 s 5.7 s +0.5 stops
8 s 14 s +0.8 stops
15 s 30 s +1 stops
30 s 1 min 13 s +1.3 stops
1 min 2 min 54 s +1.5 stops
2 min 6 min 57 s +1.8 stops
4 min 16 min 38 s +2.1 stops
8 min 39 min 50 s +2.3 stops
16 min 1 h 35 min +2.6 stops
Other films with reciprocity data

Other films with reciprocity data

The reciprocity calculator ›